So what value of ST1 should we return when we read Sector 96? If only someone had written a handy dandy Floppy Drive Controller reference. oh wait

Replies (1)

  • @gloriouscow@oldbytes.space 2026-07-30 20:35

    Bit 5 is what we're looking for. We need to set this bit because we encountered a bad address CRC. Right now i'm setting bit 2, saying I can't find the data field, which is arguably true, but that's just not correct in this case.

    Open ##4253266