Elektrine lite

← Feed

@preya@mastodon.social

Post #1733427

2024-10-13 08:19 UTC

@malte I have the ADS-1700W and it’s driving me mad, because it forgets date/time when it’s shut off and it takes at least 60min to get it via NTP after turning it on. Is this still present on the ADS-1800W?

Replies (1)

  • @malte@frankfurt.social 2024-10-13 08:52

    @preya Interesting. I hadn't even set the date/time until now. Is this important to have? I gave it a short test: I set the date and time and then cut the power for five minutes. Afterwards the date and time was still correct. I also configured SNTP now and the smallest update interval seems to be one hour, which would fit your problem description.

    Open ##1733428